our Online Store has been opened, please visit www.LoggerOnline.com
2 or 3 Year Maintenance-Free Gas Detector H2S, SO2, CO or O2
The GasAlertClip Extreme offers unequaled protection in two and three year versions, with no sensor replacement, no calibration and no downtime. With zero maintenance costs and continuous around the clock monitoring, the GasAlertClip Extreme is a cost effective solution. Also compatible with the MicroDock II automatic test and calibration system.
Protect Yourself:
-
Simple operation—one-button activation, test and data transmission
-
Continuous, alphanumeric, status LCD shows detector life remaining, alarm setpoints and advises self-test status
-
Built-in concussion-proof boot
-
Records and displays the peak alarm encountered and the time elapsed since the exposure occurred
-
Automated bump test with BW’s MicroDock II system
-
Automatic event logging records 10 most recent alarm events; downloadable to a printer, computer or MicroDock II
-
Loud (95 dB typical) audible alarm, bright, quad-LED indicators and internal vibrator alarm come standard
-
Compact and lightweight
-
Rugged, IP 66/67 highly water-resistant design
-
Full function self-test of audible/visual and vibrator alarms, integrity of sensor, battery and circuitry
Ordering Information
2 Year GasAlertClip Extreme Detectors with Event Logging
GA24XT-H H2S detector
GA24XT-M CO detector
GA24XT-S SO2 detector
GA24XT-X O2 detector
3 Year GasAlertClip Extreme Detectors with Event Logging
GA36XT-H H2S detector
GA36XT-M CO detector
MicroDock II Automatic Test and Calibration System
DOCK2-2-1E-00 MicroDock II base station and H2S docking module
DOCK2-2-1F-00 MicroDock II base station and SO2 docking module
DOCK2-2-1G-00 MicroDock II base station and CO docking module
DOCK2-2-1H-00 MicroDock II base station and O2 docking module
Note: Add suffi x by region:
North America: -N Europe: -E United Kingdom: -U Australia: -A
Accessories
GA-USB2 IR DataLink
GPR-PRINTER2 Infrared cordless printer
GA-TS02 GasAlertClip automatic test station
GA-HC-1 Hard hat clip (for use with alligator clips)
GA-AG-1 Alligator clip (non-conductive)
GA-CL-1 Belt clip (stainless steel)
GA-NS-1 Neck strap with safety release
GA-TC-1 Test cap and hose
GA-CDT-1 Interactive training CD
SPECIFICATIONS
DETECTOR: Zero-maintenance detector
|
Gas monitored
|
H2S
|
CO
|
SO2
|
O2
|
|
Sensor range
|
0-100 ppm
|
0-300 ppm
|
0-100 ppm
|
0-30.0 % by vol.
|
|
Low alarm level1
|
10 ppm
|
35 ppm
30 ppm (UK/EU)
|
5 ppm
|
19.50%
|
|
High alarm level1
|
15 ppm
|
200 ppm
|
10 ppm
|
23.50%
|
|
Operating temperature2
|
-40 to +122°F
-40 to +50°C
|
-22 to +122°F
-30 to +50°C
|
22 to +122°F
-30 to +50°C
|
-4 to +122°F
-20 to +50°C
|
|
Calibration
|
Not required
|
Self-calibrating
|
1Customized alarm settings available at no extra charge
2Internal vibrator operates to +5°F / -15°C
|
GENERAL SPECIFICATIONS:
|
Rugged composite material with integral concussion-proof boot
|
|
Humidity:
|
5% to 95% RH (non-condensing)
|
|
EMI/RFI:
|
Complies with EMC Directive 89/336/EEC
|
|
Ingress protection:
|
IP 66/67
|
|
Battery:
|
Lithium, non-replaceable
|
|
Continuously on:
|
Yes
|
|
One-button control:
|
Activation, self-test and alarm event data transmission
|
|
Full functional self-test:
|
Verifi es integrity of sensor, circuitry, battery and audible/visual alarms
|
|
Sensor:
|
Electrochemical cell (temperature compensated)
|
|
Operational life:
|
Two years (H2S, CO, SO2 or O2) or three years (H2S or CO)
|
|
|
|
|
INDICATORS AND ALARMS:
|
|
|
Visual alarm:
|
Flashing, wide-angled alarm lens with red quad-LEDs, plus fl ashing ALARM icon
|
|
Audible alarm:
|
Pulsing, high-output siren at 95 dB (typical) at 1 ft. (0.3 m)
|
|
Vibrator alarm:
|
Internal
|
|
Failure alarm:
|
Yes (audible/visual/vibration)
|
|
Self-test pass:
|
Yes (audible/visual/vibration)
|
|
Other:
|
End of life (audible/visual/vibration)
|
|
|
|
|
CONTINUOUS LCD DISPLAY:
|
Status display
|
|
Life remaining:
|
Continuously displayed in months, days, then hours
|
|
Two alarm levels:
|
LOW alarm / HIGH alarm
|
|
Peak alarm exposure:
|
Records and displays peak alarm exposure value and time elapsed (up to 24 hours)
|
|
Alarm setpoints:
|
High and low (displayed on demand in ppm or %)
|
|
Self-test status:
|
Advises to “TEST” and that self-test was passed “”
|
|
|
|
|
TESTS:
|
|
|
Full function self-test:
|
On activation and every 20 hours
|
|
Battery:
|
Every two hours (auto)
|
|
|
|
|
EVENT LOGGING:
|
Records and transmits up to 10 gas alarm events
|
|
Event information:
|
Gas type, peak exposure level (ppm or %); alarm duration in minutes and seconds;
time elapsed since the alarm occurred in days, hours and minutes, life remaining,
serial number, self-tests performed, total number and duration of all events encountered
|
|
Transmission method:
|
Via infrared port to infrared printer or to an IR DataLink
|
|
|
|
|
PHYSICAL SIZE:
|
|
|
Size:
|
1.1 x 2.0 x 3.2 in. / 28 x 50 x 81 mm
|
|
Weight:
|
2.7 oz. / 76 g
|
|
WARRANTY:
|
2 years from activation (given normal operation); 1-year shelf life
|
|
|
|